What causes an AC to trip the main DEWA circuit breaker repeatedly?

Short answer: A shorted compressor winding, a failing capacitor causing high start current, a burnt contactor, loose or corroded terminals, or water reaching wiring. An undersized breaker on a large unit can also trip. Repeated tripping is a fire risk, so do not keep resetting it. A technician should measure the current draw and insulation resistance.

By the AC Clinic technical team, Dubai. Updated 21 November 2026.

Detailed answer

When an AC repeatedly trips the breaker in your DEWA distribution board, the protection device is doing its job: it has detected too much current or a fault to earth. The causes range from simple to serious. A failing start capacitor makes the compressor draw very high current every time it tries to start. A burnt or pitted contactor creates arcing. Loose, overheated terminals or water reaching the outdoor unit wiring can cause earth faults.

The serious cause is a compressor with a shorted or grounded winding. That compressor will keep tripping the breaker and usually needs replacing. An undersized breaker or cable on a large villa unit (5 to 13 TR) can also cause nuisance tripping, especially on hot afternoons when the current draw peaks.

Resetting a breaker again and again is dangerous because the cabling heats up each time. A technician should measure the running and starting current, test the capacitor, inspect the contactor, and check the compressor windings with an insulation tester.

What to check

  • Note whether the breaker trips immediately or after some minutes of running
  • Check for water around the outdoor unit or isolator after rain or washing
  • Do not reset more than once; switch the unit off at the isolator
  • Ask the technician for the insulation resistance reading on the compressor

What it costs in Dubai

Capacitor and contactor repairs usually fall between AED 149 and AED 300 fitted. Compressor faults are quoted after testing.

See the full AC Clinic price list →

Get help from an AC specialist

AC Clinic works only on air conditioning in Dubai villas and townhouses, from wall splits to 13 TR ducted and package units. Send a short video of your unit on WhatsApp and a technician will tell you what they think is wrong before visiting.

Related questions

All 25 questions in Emergency AC Repairs & Troubleshooting →

AC not cooling? We can usually be there today.

Call or WhatsApp +971 56 253 7625. Working hours 8 AM to 10 PM daily except Sunday, emergency line 24/7.